Thursday, 20 January 2022

Implementation of Shortest Control Path Finder for a Hybrid Electrical Vehicle Control using Matlab Simulink


Implementation of  Shortest Control Path Finder for a  Hybrid Electrical Vehicle Control  using Matlab Simulink



This example shows how to find the shortest control path for a hybrid electrical vehicle using Signal Tracing Command-line API. In this model, a Hybrid Electrical Vehicle drives on a slope and the initial speed is 0 m/s. Set the target speed to 30 m/s. In Driver, a PID control compares the actual speed with the target speed and sends a command to increase or decrease speed to the power demand estimation module.  Power demand estimation converts to the desired power, and the power is primarily provided by the electrical motor. If electrical motor is unable to provide enough torque, then the engine and provides additional torque. In Vehicle Dynamic, road resistance including rolling resistance and gravity resistance as well as the aero drag are calculated. The actual speed of the vehicle is constantly returned to Driver through the feedback loop until the vehicle reaches the target speed. 1) Trace All Sources that Control the Actual Speed 2)Obtain the Trace Graph 3) Find the Shortest Path from Trace graph 4) Simulation : Shortest Control Path for a Hybrid Electrical Vehicle Click here to download the demo files: https://drive.google.com/file/d/1NU4jML0j8DzMxP0Z43Q9okayTCyolLPf/view?usp=sharing https://drive.google.com/file/d/1XRuV44_9TzpHn6G2qJ0rOnLEL29yhai4/view?usp=sharing Kindly Subscribe My YouTube Channel... Please like, share and comments on My Videos 🙏 Please click the below links to Subscribe/Join & View my Videos https: //www.youtube.com/c/DrMSivakumar For More Details about this Video Join/ View the following Telegram : t.me/Dr_MSivakumar website : drmsivakumar78.blogspot.com



Sunday, 16 January 2022

Design & Analysis of Indoor Digital TV Rx & Broadcasting System using Discone Antenna



Design & Analysis of Indoor Digital TV Rx & Broadcasting System using Discone Antenna

This example shows how to design and implement a discone antenna for indoor use in digital TV receiving and transmitting systems. 

Discone antennas are wide bandwidth and omnidirectional radiation antennas that are widely used in VHF and UHF broadcasting systems. 

The described antenna provides matched bandwidth, below -10 dB of return loss, between 460 MHz and 2.3 GHz, and provides omnidirectional radiation pattern within the considered TV band, from 470 MHz to 862 MHz. 

Matlab Script:

%% Discone Antenna for Indoor Use TV Receiving & Broadcasting System

% This example shows how to design and implement a discone antenna for indoor use in digital TV receiving and transmitting systems. 

%% Define Parameters
Rd  = 55e-3;                % Radius of disc
Rc1 = 72.1e-3;              % Broad Radius of cone
Rc2 = 1.875e-3;             % Narrow Radius of cone
Hc  = 160e-3;               % Vertical height of cone
Fw  = 1e-3;                 % Feed Width
S   = 1.75e-3;              % Spacing between cone and disc

%% Create Discone Antenna
% Create a discone antenna using the defined parameters.
ant = discone;
ant.Height = Hc;
ant.ConeRadii  = [Rc2 Rc1];
ant.DiscRadius = Rd;
ant.FeedHeight = S;
ant.FeedWidth  = Fw; 
figure;
show(ant);
title('Discone Antenna Element');

%% S-Parameters
freq = (0.1:0.01:3)*1e9;
[~] = mesh(ant,'MaxEdgeLength',10e-3);
s1 = sparameters(ant,freq);
rfplot(s1);

%% Radiation Pattern
f = 470e6;
figure;
pattern(ant,f);

%% Elevation Pattern
p1 = patternElevation(ant,470e6);
p2 = patternElevation(ant,862e6);
p3 = patternElevation(ant,1.5e9);
p4 = patternElevation(ant,3e9);
figure;
polarpattern(p1);
hold on;
polarpattern(p2);
polarpattern(p3);
polarpattern(p4);
legend ({'470MHz' '862MHz' '1500MHz' '3000MHz'});



Tuesday, 11 January 2022

Design and Control of Dual Active Bridge Converter For Grid-Tied Inverters


Design and Control of Dual Active Bridge Converter For Grid-Tied Inverters


This example shows standard control with 50% duty cycle on both bridges and phase shifting to control output voltage. It works well with a variable step solver as the PWM generator is designed for continuous time domains. Adrián Casado (2022). https://in.mathworks.com/matlabcentral/fileexchange/63442-dual-pv-generator-mppt-boost-h-bridge-cascaded-inverter A dual active bridge is a bidirectional DC-DC converter with identical primary and secondary side full-bridges, a high frequency transformer, an energy transfer inductor and DC-link capacitors. Each switch is on for 50% of its respective switching period. The switch pairs in the two bridges all have the same switching period but are operated such that between each bridge a phase shift is introduced that varies based on the modulation derived from feedback measurements. An output voltage error signal is generated based on a set point value and this is fed through a digital PI regulator to generate the phase shift ratio for the PWM modulator. Kindly Subscribe My YouTube Channel... Please like, share and comments on My Videos 🙏 Please click the below links to Subscribe/Join & View my Videos https: //www.youtube.com/c/DrMSivakumar Telegram : t.me/Dr_MSivakumar Click here to get the simulink file: https://drive.google.com/file/d/1YlSt1-aH_zunGItDoWBGhD103DolSVPw/view?usp=sharing For More Details Visit My Website: website : drmsivakumar78.blogspot.com https://www.paypal.com/paypalme/DrMSivakumar?locale.x=en_GB



Monday, 10 January 2022

Two-Diode PV Model with Cascaded H-bridge Multilevel Inverter for Grid-connected Applications


Two-Diode PV Model with  Cascaded H-bridge Multilevel Inverter for Grid-connected Applications


This example shows the Dual Diode Photovoltaic Model Cascaded H-Bridge Multilevel PV Inverter with MPPT Booster Algorithms for Grid Connected Applications
Ref: Adrián Casado (2022). https://in.mathworks.com/matlabcentral/fileexchange/63442-dual-pv-generator-mppt-boost-h-bridge-cascaded-inverter
1) Simulink Model – Dual Diode PV Model with Cascaded H-Bridge Multilevel PV Inverter_ Phase-shifted SPWM (PS-SPWM) switching scheme is then applied to control the switching devices of each H-bridge.
2) MPPT Algorithms & Cascaded H-bridge 3 Level Inverter
3) Scope 1: Experimental power extracted from PV panels with MPPT_ The harvested solar power waveform of each phase with MPPT Booster Algorithms
4) Scope 2: Experimental inverter output voltages with modulation compensation _Cascaded H Bridge 3 Level Inverter output Voltage Wave form
5) Scope 3: Voltage, Current Measurements

Click here to download the simulink file: https://drive.google.com/file/d/1uKIqsawmhXAj1AIphu1T0sXG-uThn7Qg/view?usp=sharing





Sunday, 9 January 2022

Single-Diode Photovoltaic Model with Efficient MPPT Booster Algorithms Using Matlab Simulink



Single-Diode Photovoltaic Model with  Efficient MPPT Booster Algorithms Using Matlab Simulink


This example shows the Single-Diode Photovoltaic Model for Efficient I-V Characteristics Estimation with MPPT Booster Algorithms Reference: Adrián Casado (2022). https://www.mathworks.com/matlabcentral/fileexchange/63385-single-diode-pv-mppt-boost-model Click here to download the simulink file: https://drive.google.com/file/d/1xb5L206K9yCtyit846o2s0qVy1y4Lj3F/view?usp=sharing



Uploaded Matlab Videos